Features & Benefits

  • 2 year parts and labour warranty*
  • Compact floor-standing design is ideal for replacement situations
  • User friendly status display
  • Range of outputs available
  • ErP compliant
  • Temperature control and diagnostics for rapid servicing
  • Optional remote user kit
  • Boiler frost protection

Warranty

*2 year parts and labour warranty available when registered within 30 days of installation and serviced annually. *Subject to Terms and Conditions.

  • Test Uk 3 DESIGNED IN THE UK
  • Badge Digi Display LARGE COLOUR SCREEN
  • Badge Compact COMPACT
  • 2 Year Warranty Badge 2 YEAR WARRANTY
  • Badge Frost Protection HOT WATER IN SUNSHINE, RAIN, ICE AND SNOW
  • Badge Flue Variants FLUE VARIANTS
  • Badge Nox Class 6 NOX CLASS 6
  • Badge ERP ERP COMPLIANT

Technical Specification

Perfect for situations when replacing an old floor standing standard efficiency boiler. Mexico is highly efficient, recommended by the Energy Saving Trust and comes complete with a 2 year parts and labour warranty as standard.

MEX 15 MEX 18 MEX 24 MEX 30 MEX 36
Height mm 850 850 850 850 850
Width mm 450 450 450 450 450
Depth mm 530 530 530 530 530
Weight (packaged) kg 55.4 55.4 55.4 69 69
Max installation weight kg 52 52 52 68 68
CH output (kW) min/Max @ 70°C 8.8 - 14.6 8.8 - 18.2 8.8 - 23.4 10.6 - 30.1 10.6 - 37.0
CH output (kW) min/Max @ 40°C 9.6 - 15.5 9.6 - 19.2 9.6 - 25.1 11.4 - 32.8 11.4 - 39.8
DHW output (kW) max n/a n/a n/a n/a n/a
DHW flow rate I/min. 35°C rise n/a n/a n/a n/a n/a
SEDBUK rating (2005) % 90.4 90.3 90.2 90.4 90.7
NOx classification CLASS 6 CLASS 6 CLASS 6 CLASS 6 CLASS 6
Adjustable to LPG No No No No No
Max horizontal 6m 6m 6m 3m 3m
Max vertical 7.5m 7.5m 7.5m 5m 5m
Powered vertical No No No No No
Condensing boiler Yes Yes Yes Yes Yes
Low temperature boiler No No No No No
B1 boiler No No No No No
Equipped with a supplementary heater No No No No No
Cogeneration space heater No No No No No
Combination heater No No No No No
Nominal heat output for space heating
Full load P4 kW 14.8 18.3 23.8 30.1 37.1
Part load P1 kW 5.0 6.1 7.9 9.9 12.1
Auxiliary electricity consumption
Full load ELmax kW 00.38 00.38 00.38 0.042 0.042
Part load ELmin kW 0.024 0.024 0.024 0.028 0.028
Standby Psa kW 0.01 0.01 0.01 0.01 0.01
Seasonal space heating energy efficiency
Full load ŋ4 % 88.5 88.2 87.9 88.5 89.0
Part load ŋ1 % 99.0 98.5 97.1 97.2 97.3
Standby loss Pstby kW 0.055 0.055 0.055 0.055 0.055
Ignition Pign kW 0 0 0 0 0
Emissions NOx mg/kWh 16 13 19 20 25
Annual Energy consumption Qhe GJ 46 57 75 94 116
Sound power level, indoors Lwa dB 40 41 42 45 45