Our cost-effective and simple-to-use Mexico HE Heat Only boilers come with a two year warranty*, a compact design and flexible siting. Available in a range of outputs, these ErP compliant models also include temperature control and diagnostics for rapid servicing. The Mexico HE line of floor-standing heating systems is the perfect solution for replacement installations, especially if the new boiler needs to be a certain height from the floor.
*2 year parts and labour warranty available when registered within 30 days of installation and serviced annually. *Subject to Terms and Conditions.
Perfect for situations when replacing an old floor standing standard efficiency boiler. Mexico is highly efficient, recommended by the Energy Saving Trust and comes complete with a 2 year parts and labour warranty as standard.
MEX 15 | MEX 18 | MEX 24 | MEX 30 | MEX 36 | |
---|---|---|---|---|---|
Height mm | 850 | 850 | 850 | 850 | 850 |
Width mm | 450 | 450 | 450 | 450 | 450 |
Depth mm | 530 | 530 | 530 | 530 | 530 |
Weight (packaged) kg | 55.4 | 55.4 | 55.4 | 69 | 69 |
Max installation weight kg | 52 | 52 | 52 | 68 | 68 |
CH output (kW) min/Max @ 70°C | 8.8 - 14.6 | 8.8 - 18.2 | 8.8 - 23.4 | 10.6 - 30.1 | 10.6 - 37.0 |
CH output (kW) min/Max @ 40°C | 9.6 - 15.5 | 9.6 - 19.2 | 9.6 - 25.1 | 11.4 - 32.8 | 11.4 - 39.8 |
DHW output (kW) max | n/a | n/a | n/a | n/a | n/a |
DHW flow rate I/min. 35°C rise | n/a | n/a | n/a | n/a | n/a |
SEDBUK rating (2005) % | 90.4 | 90.3 | 90.2 | 90.4 | 90.7 |
NOx classification | CLASS 6 | CLASS 6 | CLASS 6 | CLASS 6 | CLASS 6 |
Adjustable to LPG | No | No | No | No | No |
Max horizontal | 6m | 6m | 6m | 3m | 3m |
Max vertical | 7.5m | 7.5m | 7.5m | 5m | 5m |
Powered vertical | No | No | No | No | No |
Condensing boiler | Yes | Yes | Yes | Yes | Yes |
Low temperature boiler | No | No | No | No | No |
B1 boiler | No | No | No | No | No |
Equipped with a supplementary heater | No | No | No | No | No |
Cogeneration space heater | No | No | No | No | No |
Combination heater | No | No | No | No | No |
Nominal heat output for space heating | |||||
Full load P4 kW | 14.8 | 18.3 | 23.8 | 30.1 | 37.1 |
Part load P1 kW | 5.0 | 6.1 | 7.9 | 9.9 | 12.1 |
Auxiliary electricity consumption | |||||
Full load ELmax kW | 00.38 | 00.38 | 00.38 | 0.042 | 0.042 |
Part load ELmin kW | 0.024 | 0.024 | 0.024 | 0.028 | 0.028 |
Standby Psa kW | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 |
Seasonal space heating energy efficiency | |||||
Full load ŋ4 % | 88.5 | 88.2 | 87.9 | 88.5 | 89.0 |
Part load ŋ1 % | 99.0 | 98.5 | 97.1 | 97.2 | 97.3 |
Standby loss Pstby kW | 0.055 | 0.055 | 0.055 | 0.055 | 0.055 |
Ignition Pign kW | 0 | 0 | 0 | 0 | 0 |
Emissions NOx mg/kWh | 16 | 13 | 19 | 20 | 25 |
Annual Energy consumption Qhe GJ | 46 | 57 | 75 | 94 | 116 |
Sound power level, indoors Lwa dB | 40 | 41 | 42 | 45 | 45 |