Features & Benefits

  • COP: up to 4.52 (+7°C/+35°C)
  • Compatible with all kinds of low temperature transmitters
  • Intuitive control and simplified use
  • Navistem 400S regulator
  • 3kW Electrical back-up integrated
  • Integrated 16L buffer tank
  • Patented coaxial heat exchanger
  • Inverter regulation

Warranty

Flexible warranties available.

Technical Specification

Designation Unit Alfea Extensa A.I 5 Alfea Extensa A.I 6 Alfea Extensa A.I 8 Alfea Extensa A.I 10
MCS ref KIWA 00027/017 HP KIWA 00027/018 HP KIWA 00027/019 HP KIWA 00027/020 HP
Heat Pump Space Heating [35°C]
ErP Rating A+++ A+++ A+++ A+++
ηₛ 175% 175% 177% 159%
SCOP 4.39 4.38 4.46 4.51
Heat Pump Space Heating [55°C]
ErP Rating A++ A++ A++ A++
ηₛ 125% 125% 128% 117%
SCOP 2.92 3.15 3.22 3.28
Heating (A7/W35)
Capacity (kW) 4.50 5.50 7.50 9.50
Power Input (kW) 0.95 1.18 1.69 2.11
COP 4.74 4.64 4.43 4.50
Air Temperature Range (°C)
Min/Max -20/ +35 -20/ +35 -20/ +35 -20/ +35
Sound Data Outdoor Unit / Indoor Unit
Pressure Level 5m Outdoor / 1m Indoor dB(A)* 35/32 35/32 38/32 39/32
Power Level dB(A)** 57/40 57/40 60/40 60/40
MCS 020 (Q2) 4m to assessment point Visable Visable Barrier (partial view) Barrier (partial view)
42dB(A) | Pass 42dB(A) | Pass 42dB(A) | Pass 42dB(A) | Pass
Primary Flow Rate
Min / Max (l/min) 8.1/16.2 9.9/19.8 13.5/26.9 17.01/34.12
Pipework Connection Sizes
Heating F/R (mm) 28 28 28 28
Gas Pipe - refrigeration (in) 1/2 1/2 1/2 5/8
Liquid Pipe - refrigeration (in) 1/4 1/4 1/4 3/8
Dimensions Outdoor Unit (mm)
Width 866 866 907 940
Depth 325 325 349 365
Height 632 632 716 996
Dimensions Indoor Unit (mm)
Width 448 448 448 448
Depth 493 493 493 493
Height 847 47 847 847
Weight (kg)
Outdoor Unit / Indoor Unit 39/42 39/42 42/42 60/46
Electrical Data
Electrical Supply (50 Hz) 230 V 230 V 230 V 230 V
Phase Single Single Single Single
Maximum Running Current [Nominal] (A) 13 13 18 19
Back-up Heater (kW) 3 3 3 3
Fuse Rating - MCB Sizes Type D (A)***** 16 16 25 25
Refrigerant Charge (kg)****
R32 0.97 0.97 1.02 1.63

*ErP in accordance with EN 14825, EN 12102-1, EN 14511, EN 16147. The energy efficiency provided may not correspond to the actual energy once installed in a building, as the efficiency is influenced by other factors such as heat loss in the distribution system and the capacity of the products in relation to building size and characteristics. *Hydraulic unit: Sound pressure level at 5m from the appliance, 1.5m off the ground, open field directionality 2 / Outdoor unit : Sound pressure level at 5m from the device, halfway between the ground and top of the outdoor unit, open field directionality 2. **The EN 12102-1, sound power level is a laboratory measurement of the emitted sound power. It does not correspond to a measurement of the perceived sound power. **** Calculation in accordance to MIS:MCS 020 Issue 1.3. Thermal and acoustic performances are measured with 7.5m length refrigerant lines. ***** Fuse rating for Outdoor Heat Pump Unit 

Useful Resources

Need help with your boiler or control? Download our guides for more technical information on your boiler.

How to buy

Find an Ideal installer

Only fully trained and Gas Safe Registered installers can fit Ideal boilers, so step 1 in your purchase is to choose your local Ideal installer.