Features & Benefits

  • Highly efficient: SCOP up to 5.19*
  • Quiet Mark Approved
  • Compatibility: radiator and underfloor heating systems
  • Intuitive control: smart weather compensating controls
  • Low carbon refrigerant: zero ozone depletion and low global warming potential
  • Smart grid and solar PV compatible
  • Monobloc technology enables easy installation and servicing
  • Domestic hot water: hot, efficient and fast re-heat times with the Ideal heat pump cylinder range

The Ideal heat pump package combines three revolutionary products:

  • 1. Our quiet, compact and highly efficient monobloc heat pump
  • 2. Our industry leading pre-plumbed heat pump cylinder
  • 3. The Halo Air heat pump thermostat

Our heat pumps are designed to work in new build and retrofit installations, working with traditional radiators and underfloor heating.

  • Test Uk 3 DESIGNED FOR THE UK CLIMATE
  • Badge Frost Protection HOT WATER IN SUNSHINE, RAIN, ICE AND SNOW
  • Energy Efficiency 519 Scop Rating Badge 1 SCOP rating up to 519%
  • Customer Service Badge 364 days a year UK customer service
  • Quiet Badge Quiet operation
  • Badge Quiet Mark QUIET MARK

Technical Specification

Available in two different outputs of 8kW & 10kW.

Designation Unit 4kW 5kW 8kW 10kW
Ideal Product Code
AH750664 AH750665 AH750666 AH750667
MCS Certification No.
KIWA 00027/024 HP KIWA 00027/023 HP KIWA 00027/021 HP KIWA 00027/022 HP
PCDB Index Number
Flow Temp 35°C 107447 107235 106762 106754
Flow Temp 45°C 107446 107234 106761 106753
Flow Temp 55°C 107445 107233 106760 106752
Heat Pump Space Heating [35°C]*
ErP Rating A+++ A+++ A+++ A+++
ƞs 195 200 203 205
SCOP (EN14825) 4.96 5.07 5.16 5.19
Heat Pump Space Heating [55°C]*
ErP Rating A++ A++ A++ A++
ƞs 136 143 145 146
SCOP (EN14825) 3.48 3.65 3.7 3.73
Heating [A 7°C / W 35°C]*
Capacity (kW) 4 5 8.2 10.3
Power Input (kW) 0.75 0.97 1.58 2.1
COP 5.34 5.0 5.19 4.9
Heating [A 7°C / W 55°C]*
Capacity (kW) 4.0 5.0 8.2 10.3
Power Input (kW) 1.33 1.64 2.67 3.42
COP 3.0 3.04 3.07 3.01
Sound Power Level (EN 12102 - 1)
35°C db(A) 52 52 55 55
55°C db(A) 52 52 55 55
Pipework Connection Sizes
Heating F/R (mm) 28mm 28mm 28mm 28mm
Dimensions Outdoor Unit (mm)
Width 1095 1095 1095 1095
Depth 518 518 518 518
Height 798 798 1008 1008
Weight (kg)
Outdoor Unit 86 86 110 110
Electrical Data
Electrical Supply (50 Hz) 230v 230v 230v 230v
Phase Single Phase Single Phase Single Phase Single Phase
Refrigerant Charge (kg)*
R32 0.88 0.88 1.47 1.47

Certification EN 14511:2018, EN 14825:2016, EN 12102 - 1:2022

*Performance data  in accordance with EN 74825, EN 12102-1,  EN 74577. The energy efficiency provided may not correspond to the actual energy once installed in a building, as the efficiency is influenced by other factors such as heat loss in the distribution system and the capacity of the products in relation to building size and characteristics.